Lasting protection,
optimal performance

Durafin™ Ultra

Safeguard the Heat Exchanger from damaging corrosion. The Durafin™ Ultra has an anti-corrosive layer and a hydrophilic layer that protect the Heat Exchanger from rust. Its superb corrosion-resistance was proven in a Salt Spray Test (SST)*.



  • * Based on testing by a third party lab in accordance with ASTM B117, an official test method. For more details, please contact Samsung’s technical professionals.
  • ** Based on testing by a third party lab, applying the actual pressure of refrigerant for 1 minute, after a Salt Spray Test (SST) of over 2,280 hours.
  • * Based on testing by a third party lab in accordance with ASTM B117, an official test method. For more details, please contact Samsung’s technical professionals.
  • ** Based on testing by a third party lab, applying the actual pressure of refrigerant for 1 minute, after a Salt Spray Test (SST) of over 2,280 hours.

Cost-effective and flexible design

Slimmer Liquid Pipe

Save installation cost with efficient piping. It uses 28% less refrigerant* as it can use a slimmer liquid pipe**. So it reduces installation and maintenance costs and improves design flexibility. It’s also environmentally friendly and reduces CO₂ emissions.

  • * When a slimmer pipe, instead of a normal pipe, is used for the Main Liquid Pipe on the same capacity of air conditioning system, the amount of refrigerant to be charged can be reduced by 28% on average.
  • ** Optional. A slimmer pipe can be used for the Main Liquid Pipe, between an outdoor unit and the first branch of indoor units. The diameter of the slimmer pipe will vary depending on the diameter of the pipe that is normally used. Not available on the 22.4kW and 28kW models. It may not be available in certain installation conditions, and is not compatible with the AI functions of outdoor units. Please contact Samsung’s technical professionals regarding its availability and for more detailed information.
  • * When a slimmer pipe, instead of a normal pipe, is used for the Main Liquid Pipe on the same capacity of air conditioning system, the amount of refrigerant to be charged can be reduced by 28% on average.
  • ** Optional. A slimmer pipe can be used for the Main Liquid Pipe, between an outdoor unit and the first branch of indoor units. The diameter of the slimmer pipe will vary depending on the diameter of the pipe that is normally used. Not available on the 22.4kW and 28kW models. It may not be available in certain installation conditions, and is not compatible with the AI functions of outdoor units. Please contact Samsung’s technical professionals regarding its availability and for more detailed information.

Automatically
improved efficiency

Active AI Technologies

Optimize cooling automatically! Active AI Pressure Control* intelligently adjusts the condensing pressure, cutting energy use by 15%;**. Active AI Defrost increases the continuous heating time by 40%***. And Active AI Refrigerant Analysis**** optimizes the refrigerant level.

The ultimate in energy efficiency

Energy Efficiency

Cut costs with around 11% more energy efficiency*. The Heat Exchanger has 36.2% more area** to heat faster. An optimized refrigerant path improves heat transfer. A Multi-serration Fan uses 32% less electricity***. And a new IGBT reduces electricity loss by 20%****.


  • * Based on testing in accordance with the Eurovent testing rule, at the end of December 2020. Tested on 22.4~56kW models of the Samsung DVM S2 compared to the same capacities of another brand, using ducted type indoor units.
  • ** Based on Samsung†s measurements, comparing 33.6kW models of a DVM S2 and a conventional outdoor unit.
  • *** Based on internal testing, using the DVM S2 33.6kW model. A Multi-serration Fan generated 195CMM consuming 725W, while a conventional fan generated 176CMM consuming 1,057W. Results may vary depending on the individual test or usage conditions.
  • **** Based on internal testing of the DVM S2 33.6kW model compared to a conventional outdoor unit, combined with 6 GD2 5.6kW indoor units. Results may vary depending on the individual test or usage conditions.

Enabling a new era of
consistent comfort

Advanced Flash Injection Compressor

Enter a new era of non-stop comfort and efficiency. The Advanced Flash Injection Compressor provides the world’s largest capacity*. It combines Flash Injection technology with a strengthened Triple Profile Scroll and efficient Optimal Discharge Superheat (DSH) Control technology.

* Samsung circulates 14,400cc/sec refrigerant (= 90cc (displacement volume) x 160rps (revolutions per second)), while Company A circulates 12,480cc/sec (= 96cc x 130rps), Company B circulates 14,080cc/sec (= 88cc x 160rps) and Company C circulates 12,320cc/sec (= 88cc x 140rps).

Related Product

Related Product

Our Full Range of Climate Systems

Our Full Range of Climate Systems

A Resource Bank For All Things Samsung

As one of Samsung's registered Climate Solution Partners, you will have access to our Partner Portal and its many benefits.