rotary compressor
home > support > application guide

application guide

application & refrigerant LBP HBP
R-12 R-134a R600a R_134a R-22
usable
refrigerant
R-12(CC2F2).
purity of 99.
95% min.
R-134a (CH2F-
CF3).
purity of 99.
95% min.
R-134a(CH(C-
H3)5).
purity of 99.
95% min.
R-134a(CH2F-
CF3).
purity of 99.
95% min.
R-22(CHClF2).
purity of 99.
95% min
operating
voltage
Rated voltage -15% ~ +10% Rated voltage -15% ~ +10%
evaporating
temperature
-35°C ~ -15°C [Limit -35°C~ -10°C] -5°C ~ +10°C [Limit -10°C ~ +15°C]
condensing temperature
(pressure)
54°C(180psig, 12.6kg/cm²G)max[Limit 60°C(205psig. 14.5kg/cm²G)]
Peak in 43°C
pull - down:68°C
(250psig, 17.5kg/cm²G)max.
55°C(202psig, 14.2kg/cm²G)max[Limit 60°C(229psig. 16.1kg/cm²G)]
Peak in 43°C
pull - down:65°C
(259psig, 18.2kg/cm²G)max.
55°C(97psig, 6.8kg/cm²G)
max[Limit 60°C(111psig. 7.8kg/cm²G)]
Peak in 43°C
pull - down:65°C
(126psig, 8.9kg/cm²G)max.
55°C(202psig, 14.2kg/cm²G)max[Limit 60°C(229psig. 16.1kg/cm²G)]
Peak in 43°C
pull - down:
65°C(259psig, 18.2kg/cm²G)max.
47°C(248psig, 17.4kg/cm²G)maxin 26.7°C ambient
[Limit 55°C
(301psig. 21.1kg/cm²G)
in 32.2°C ambient]
Discharge gas temperature 105°C max. [Limit 120°C] at 5cm in insulated pipe surface 100°C max. [Limit115°C] at 5cm in insulated pipe surface 100°C max. in 26.7°C ambient...[Limit 115°C in 32.2°C ambient]at 5cm in insulated pipe surface
Suction gas temperature Ambient temp. -2°C ~ +1°C (Suc. pipe 15cm location) about or lower than ambienttemp. (no dew forms on suc. tube)
Winding temp of motor 120°C max, pull - down : 130°C 120°C max, in 26.7°C ambient [Limit 130°C in 32.2°C ambient]
Temperature of compressor Hot temp. 100°C max. (Amb. 43 °C), low temp. 5°C min. Hot temp. 100°C max. (Amb 32°C), low temp. 5°Cmin.
Refrigerant charging quantity Equalized pressure : 70psig (4.9kg/cm²G)max. in 43°C amb. [Limit 90 psig (6.3kg/cm²G)max.
in 43°C amb]
Equalized pressure
40 psig (2.8kg/cm²G)max. in 38°C amb.
Equalized pressure : 90 psig (6.3kg/cm²G)max. in 43°C amb. [Limits 110 psig (7.7kg/cmG)Max.in 43°C amb.] Equalized pressure : 130 psig (9.1kg/cm²G)max. in 26.7°C amb. [Limits 150 psig (10.5kg/cmG)Max. in 32.2°C amb.]
Compression ratio 10.0 max 12.7 max 12.4 max 3.9 max 3.4 max
Operating ratio 65% max. (Based on Ref. Normal - Normal condition) 65% max. (Based on Normal - Normal condition, Amb temp : 26.7°C)
On/Off cycle time 5 minutes min. (Restart limits 5 minutes min.) 6 times / hours max.
Refrigeration oil TAN 0.01mgKOH/g max. Moisture content 20 ppm max TAN 0.01mgKOH/g max. Moisture content 10 ppm max. TAN 0.01mgKOH/g max.Moisture content 20 ppm max.
Moisture content 10 ppm max. in refrigerant in operation
Evacuation of cycle Vacuum 0.08 Torr (mmHg) max. Vacuum time 40 minutes min, non - condensible gas 1% max.(vol)
Installation not to incline 5° max. in every direction
Ambient temperature 5-43°C max 5-40°C