export packing & accessory parts
- standard
accessory
parts - standard export
packing & loading
quantity (20ft container) - mounting
system - winding
diagram - test
condition
standard accessory parts

| item | application | quantity (Pcs) |
|||
|---|---|---|---|---|---|
| comp. with external CLP |
comp. with internal CLP |
BLDC comp. | |||
| type1 | type2 | ||||
| nut for terminal cover | ① | 1 | |||
| terminal cover | ② | ③ | ② | ③ | 1 |
| overload protector |
④ | - | - | - | 1 |
| spring for overload, protector hold down |
⑤ | - | - | - | 1 |
| holder thermlator | - | - | ⑥ | - | 1 |
| gasket for terminal cover | ⑦ | ⑧ | ⑦ | ⑧ | 1 |
| rubber grommet | ⑨ | 3 (63F 4 Pcs) |
|||
standard export packing & loading quantity (20ft container)
| frame | compressor quantity/carton (pcs) |
carton quantity (pcs) |
accessory box ⓔ |
loading quantity ⓣ (pcs) |
packing height | |||
|---|---|---|---|---|---|---|---|---|
| 1stage ⓐ |
2 stage ⓑ |
1stage ⓒ |
2stage ⓓ |
1stage(h1) | 2stage(h2) | |||
| 39F | 36 | 72 | 4 | 24 | 6 | 1,872 | 477 | 788 |
| 44A | 36 | 72 | 2 | 22 | 6 | 1,656 | 477 | 788 |
| 44B,44D | 36 | 72 | 4 | 16 | 6 | 1,296 | 507 | 840 |
| 44BLDC | 30 | 60 | 0 | 24 | 6 | 1,440 | 507 | 840 |
| 48F | 30 | 60 | 0 | 16 | 4 | 1,080 | 523 | 896 |
| 55F | 20 | 40 | 4 | 16 | 3 | 720 | 560 | 965 |
| 63F | 12 | 24 | 12 | 12 | 3 | 432 | 660 | 1,153 |
ex.) compressor total quantity of 44frame 8.5Btu/h model : (a)X(c)+(b)X(d)= (t) / 1,656 pcs
ex.) carton total quantity of 44frame 8.5K Btu/h model : (c)+(d)+(e)=30 Cartons

Warning/Danger
Failure to follow these instructions could result in serious personal
injury.
- Ground the equipment securely.
- Turn off power before servicing.
- Mount the terminal cover in place whenever power is
applied to this compressor. - Wear protective goggles when servicing.
- Before brazing, remove pressure from both high and low side.
- Do not use this compressor to compress air.
- Use only approved refrigerants and lubricants.
- Do not touch with bare hands during running or after stopping
instantly.
mounting system

Remark
Keep the Clearance between Washer and Isolator Grommet by
0.5-2.0mm
| frame/parts | A | B | C | D |
|---|---|---|---|---|
| 39F | 14.0 | 0.5~20. | 21.0 | 10.5 |
| 44,48,55,63F | 25.5 | 0.5~2.0 | 33.5 | 11.5 |
winding diagram



| refrigerant | R22 / R407C / R410A |
|---|---|
| condensing temp.(°C) | 54.4 |
| evaporating temp.(°C) | 7.2 |
| ambient temp.(°C) | 35.0 |
| return gas temp.(°C) | 35.0 |
| liquid temp.(°C) | 46.1 |
| item | normal | tropical |
|---|---|---|
| condensing temp.(°C) | 28.0~65.0 | 28.0~74.5 |
| evaporating temp.(°C) | -25.0~12.7 | |
| discharge temp.(°C) | Max. 115.0 | |
* evaporating temp range of 39Fr is -10.0~12.0