AC026FBNDEH 2.6KW Mini 4 Way Cassette

AC026FBNDEH

0 5 0 reviews

Recycling Batteries Responsibly

  • The European Directive on Batteries and Accumulators aims to minimise the impact of batteries on the environment and encourage the recovery of the materials they contain. In the UK, regulations on the recycling of batteries and accumulators (rechargeable batteries) were Introduced in 2009. The Waste Batteries Regulations aim to significantly increase UK collection and recycling of used portable batteries from 3% in 2007 to 25% by 2012, rising to at least 45% in 2016.

  • The battery symbol on a product or on its packaging indicates that the product must not be disposed of with general household waste. Instead, it is the consumer’s responsibility to dispose of their waste batteries at a designated collection point so that they can be recycled. The separate collection and recycling of batteries at the time of dispo sal will help to conserve natural resources and ensure that they are recycled in a manner that protects human health and the environment. A comprehensive list of battery recycling centres can be obtained from: www.recycle-more.co.uk

  • All Samsung products that are subject to the Batteries Directive are compliant with the UK battery and accumulator Requirements. In accordance with national law, SAMSUNG Electronics (UK) Ltd is a member of an approved batteries producer compliance scheme. This scheme collects, treats and disposes of batteries on Samsung’s behalf.

Need more Info?

Request information about Samsung business products, solutions and services. We will contact you shortly.

Email UsBusinessUK@samsung.com

MAKE A REQUEST

AC026FBNDEH 2.6KW Mini 4 Way Cassette

Features

  • The Samsung Mini 4 Way Cassette air conditioner’s slim and compact design allows easy installation in your narrow ceiling spaces

Fan Speed Adjustment

Fan Speed Adjustment
As a result of the ability to adjust the fan speed according to the height of the ceiling, the Mini 4 Way Cassette is fully customisable to suit the needs of individual businesses. Altering the dual in-line package (DIP) switch of the unit's printed circuit board (PCB) increases efficiency so fresh air reaches the whole room, resulting in a more even distribution.

Self-Diagnosis Mode

Self-Diagnosis Mode
The unit's self-diagnosis mode alerts users to malfunctions straight away. An error code and LED light enable engineers to identify the problem quickly, reducing the time taken to fix it. As a result, this mode allows businesses to benefit from greater efficiency with a more cost-effective operation.

MDS; Motion Detect Sensor (Optional)

MDS‡ Motion Detect Sensor (Optional)
The Mini 4 Way Cassette offers a smart solution to saving energy and costs with its optional Motion Detector Sensor (MDS), which regulates the optimal amount of airflow. It works by turning off the air conditioning system once it detects the absence of any users in the vicinity. Energy efficiency is further maximised through its ability to automatically identify and set operation patterns. MDS also reduces the contrasting effect of warm and cold airflow directly at individuals, thus creating a more constant and comfortable environment.

Auto Surround Swing

Auto Surround Swing
This innovative air conditioning unit distributes cool and warm air even further with the minimum of noise. The efficient system suits all manner of rooms, ensuring no section is overlooked.
Ideal Compact Size

Ideal Compact Size

Installing the Mini 4 Way Cassette is easy. This compact air conditioning unit can fit into one standard ceiling tile measuring 600W x 600D, meaning that alterations are unnecessary. With no extra construction work to carry out, set-up time is reduced, as is the subsequent financial impact on businesses.
Powerful Airflow

Powerful Airflow

The Mini 4 Way Cassette's wide blades create powerful airflow without wasting energy. Removing the need for multiple appliances, the indoor unit delivers cool or warm air at greater distances, making it more efficient for businesses.


Ceiling Dust Prevention

Ceiling Dust Prevention

Dirty ceilings are no longer an issue with the Mini 4 Way Cassette air conditioning unit. The newly designed panel prevents dust from gathering over long periods of operation. By controlling the direction of the airflow so that it avoids contact with the ceiling, businesses can enjoy cleaner and more elegant work spaces than ever.
High Lift-Up Drain Pump

High Lift-Up Drain Pump

The Mini 4 Way Cassette includes an optional high lift-up drain pump. This lifts condensed water up to 750mm compared with previous 700mm limits. The increased quantity provides more flexibility over where the unit is installed, offering users greater convenience than ever.


No Overflowing Drain Water

No Overflowing Drain Water

The innovative drain pump check valve prevents drained water from flowing backwards into the drain pan. Minimising the drain pan's water level in this way means businesses never have to worry about water stagnation or overflows that drip into indoor spaces. The Mini 4 Way Cassette provides fresh, clean air without contaminating the room.

tech specs

Dimension of AC026FBNDEH/EU

Type

  • Type
    MINI 4 WAY CASSETTE

Model Name

  • Indoor Unit
    AC026FBNDEH/EU
  • Outdoor Unit
    AC026FCADEH/EU

SHOW MORE SPECSExpand

System

  • Mode
    HEAT PUMP
  • Capacity
    Cooling (Min / Std / Max) [kW]
    0.99 / 2.6 / 3.5
    Cooling (Min / Std / Max) [Btu/h]
    3400 / 8900 / 11900
    Heating (Min / Std / Max) [kW]
    0.98 / 3.3 / 4.6
    Heating (Min / Std / Max) [Btu/h]
    3300 / 11300 / 15700
  • Power
    Power Input Cooling (Min / Std / Max)
    0.23 / 0.73 / 1.13
    Power Input Heating (Min / Std / Max)
    0.18 / 0.9 / 1.4
    Current Input Cooling (Min / Std / Max)
    1.6 / 3.7 / 5.5
    Current Input Heating (Min / Std / Max)
    1.2 / 4.6 / 6.6
    MCA
    10.3 (MCA)
    MFA
    12.5
  • Energy Efficiency
    EER (Nominal Cooling)
    3.56
    COP (Nominal Heating)
    3.67
    Energy GradeⅠ
    SEER 6.7 (A++)
    Energy GradeⅡ
    SCOP 4 (A+)
  • Piping Connections
    Liquid Pipe [mm]
    6.35
    Liquid Pipe [inch]
    1/4"
    Gas Pipe [mm]
    9.52
    Gas Pipe [inch]
    3/8"
    Installation Limitation [Max. Length (Outdoor to indoor)]
    20 (25)
    Installation Limitation [Max. Height (Between ID/OD)]
    15 (15)
  • Field Wiring
    Power Source Wire
    2.5
    Transmission Cable
    0.75 ~ 1.25
  • Refrigerant
    Type
    R410A
    Factory Charging
    0.95

Indoor Unit

  • Power Supply
    1, 2, 220 - 240, 50
  • Fan
    Type
    Turbo Fan
    Motor (Output)
    65
    Number of Unit
    1
    Air Flow Rate (High / Mid / Low) [CMM]
    8.5 / 7.5 / 6.5
    Air Flow Rate (High / Mid / Low) [l/s]
    141.67 / 125 / 108.33
  • Drain
    Drain Pipe
    VP25 (OD 32, ID 25)
  • Sound
    Sound Pressure (High / Mid / Low)
    33 / 31 / 27
  • External dimension
    Net Weight
    11
    Shipping Weight
    13
    Net Dimensions (W x H x D)
    575 x 575 x 250mm
    Shipping Dimensions (W x H x D)
    623 x 298 x 653mm
  • Panel Size
    Panel model
    PC4SUSMB
    Panel Net Weight
    2.7kg
    Shipping Weight
    4.2kg
    Net Dimensions (W×H×D)
    670 x 45 x 670mm
    Shipping Dimensions (W x H x D)
    714 x 106 x 724mm

Outdoor Unit

  • Power Supply
    1, 2, 220 - 240, 50
  • Compressor
    Type
    Single BLDC Rotary
    Model
    UG4C090LUDJR
    Output
    0.86
    Oil (Type)
    POE
    Oil (Initial Charge)
    320
  • Fan
    Air Flow Rate (Cooling) [CMM]
    29
    Air Flow Rate (Cooling) [l/s]
    483.33
  • Sound
    Sound Pressure ( Colling / Heating )
    46 / 47
  • External dimension
    Net Weight
    33kg
    Shipping Weight
    37kg
    Net Dimensions (W x H x D)
    790 x 548 x 285mm
    Shipping Dimensions (W x H x D)
    926 x 655 x 382mm
  • Operating Temp. Range
    Cooling
    -10 ~ 46
    Heating
    -15 ~ 24

REVIEWS (0)

Owners Overall Ratings

Your opinions about this product can be helpful to us and to anyone thinking about buying one.

Support

User Manual

2.49 MB, pdf, ENGLISH

21 Nov, 2013

Some files may not be available from phones and tablets. Access this page from your desktop computer to be able to download all files.In order to read a PDF file, you must have Adobe Acrobat reader installed on your computer. You can download it at the Adobe website.Download Adobe Acrobat ReaderGoIn order to read DjVu files, you must have the DjVu viewer installed on your computer. Click this banner and install the viewer.Download Djvu ViewerGo

Have a question or need product support? Go to our support sectionGo

  • NEWEST
  • MOST HELPFUL
  • HIGHEST RATING
  • LOWEST RATING