the greening of workplaces


Samsung Electronics applies environment management program and in order to minimize contaminant discharge through strict management and process improvement of place of origin in order to minimize environment contamination material generated during manufacturing process. Under a principle of self management of waste materials by oneself, we operate the aggressive activity to preserve resources and nature by expanding process facility and recycling facility.

management of environment pollution material

pollutants by raw materials and subsidiary materials (used in the national workplaces)
unit: ton/year
type volume
Air Pollutants 55
Waste Water 364
Waste 360,211

management of air pollution material

Samsung Electronics has been making an great effort to preserve environment by altering the boiler fuel into LNG since 1994 to minimize air pollution material emission and managing contamination by real time base by introducing processing materials and new technology for prevention facility and also installing automatic environment measurement network.

air pollutant emission status

unit : kg/year

type SOx NOx Dust NH3 HF
2001 13,276 39,180 19,428 10,685 4,857
2002 18,230 39,297 13,774 10,128 6,077
2003 8,280 47,938 14,817 11,767 6,537
2004 4,611 34,003 8,645 10,950 7,492
2005 5,171 21,834 6,320 12,641 9,193

management of water pollutant

unit : kg/year

type COD SS F HF
2001 281,706 264,868 61,198 227
2002 292,902 264,948 64,414 203
2003 523,396 612,735 79,751 179
2004 90,483 70,312 111,807 207
2005 163,181 60,331 140,198 310
water pollutant status
type ㎥/million won 1,000 ㎥/year
2001 85 27,439
2002 75 30,322
2003 78 32,745
2004 66 37,794
2005 67 50,121
industrial water usage

reduction of industrial water and waster water due to the expansion of reuse.

The water utility by Samsung Electronics is divided into industrial water and public water. And we continue to expand improvement to decrease water utility and decrease the water utility by process improvement and reusability technology. For example, we decrease the use of water utility by reusing processed water as sanitary water of restroom, gardening water, and graywater.

type reusing
(thousand
㎥/year)
reusing
percentage
2001 16,754 61.1
2002 18,790 62
2003 19,078 56.2
2004 28,649 75.8
2005 35,770 71.4
water usage amount and percetage by reusing
type ㎥/million
won
thousand
㎥/year
2001 64 20,666
2002 47 19,129
2003 57 24,132
2004 53 30,624
2005 76 43,501
waste water occrrence amount

reduction cases of water pollutants

  1. the application of membrane bio system in waste water purification unit.

    Suwon Complex has applied Membrane Bio System in order to minimize water pollutant emission during washing laboratory. Since it's not possible to process washing waste of 200 ton /day of which concentrations of ABS, the surfactant is equivalent to 58.40mg/L with general activated sludge process. Therefore, we installed high-cost membrane separation system into the aeration tank through numerous pilot test.

    Membrane Bio System is the high end ultra precision filter that enables to filter pollutants in the contaminated water through particulate port (0.1~0.4μm) which exists on the membrane surface.
    According to testing results after installation, ABS treated water of pollutants is discharged at the level of 0.05mg/L Also COD and SS was drastically reduced so we plant to apply membrane bio system for the construction and expansion of waste water treatment and sewage management.

  2. waste management

    Samsung Electronics promotes to reduce waste in all production bases. We recycle the waste organic solvent which was incinerated after being discharged with other materials by pipe separation process. In addition to this, we have recycled forty thousand ton/year of organic and inorganic sludge for raw materials of cement. By reusing waste facility, materials and parts at the plant through the recycling center so we achieved the reduction effect of waste occurrence and its cost. Also we applied the polluters-pay principle into each part of plant so reduced incinerated waste occurrence by cross checking separation and upgraded recycling rate by due to expansion of recycling waste.

type ton/100
million won
ton/year
2001 0.69 223,422
2002 0.53 214,714
2003 0.56 244,048
2004 0.52 299,688
2005 0.63 361,985
discharge status
type recycling
amount (ton)
recycling
rate(%)
2001 160,302 71.0
2002 157,544 73.1
2003 198,636 78.4
2004 242,489 81.3
2005 299,043 83.0
waste recycling status

management of hazardous chemicals

  1. pre-safety evaluation on new chemicals

    New chemicals needed in each process line or research are studied by the environmental safety and health (ESH) division to determine harmful effects prior to use. This pre-safety evaluation on chemicals restricts the quantity of use of forbids use to maintain safe workplaces. For instance, a toxic cleansing agent used in reflow ovens was replaced with a surface-active agent that dramatically reduced harmful effects. The use of volatile organic compounds (VOC), including solvents, were changed to non-volatile organic compounds which removed the problem of offensive odors. Raising the ignition point from 12 °C to 120°C has minimized the risk of fire. These efforts reduced 26 tons of chemical use that returned 600.7 million Korean Won in cost reductions.

toxic substance ton/100
million won
ton/year
2001 0.179 57,960
2002 0.164 66,440
2003 0.195 84,981
2004 0.192 110,654
2005 0.247 141,921

usage if taxic chemicals