AC 100V
Model |
---|
UX0T011QNA |
Displacement | Cooling Capacity | EFF | COP | Input | Oil Charge | Net Weight | Test Condition | Dimension | |
---|---|---|---|---|---|---|---|---|---|
CC/Rev | BTU/H | W | BTU/Wh | W/W | W | cc | kg | ||
2.4 | 1,100 | 322 | 10.0 | 2.93 | 110 | 50 | 1.2 | ASHRAE HBP | 20-1 |
Model |
---|
UX0T011QNA |
Displacement | Cooling Capacity | EFF | COP | Input | Oil Charge | Net Weight | Test Condition | Dimension | |
---|---|---|---|---|---|---|---|---|---|
CC/Rev | BTU/H | W | BTU/Wh | W/W | W | cc | kg | ||
2.4 | 1,100 | 322 | 10.0 | 2.93 | 110 | 50 | 1.2 | ASHRAE HBP | 20-1 |