AE160JXYDGH/EU

EHS, Mono, Standard, Heat Pump

Capacity 16 kW, 3 PH

High Performance in Low Temperatures

EHS Mono has excellent capacity and reliability in low termperatures. Even if the temperature is lowered, the inside will stay warm and give you comfort.

High Performance in Low Temperatures
Specification
  • Features
    • Type Mono
  • Model Name
    • Outdoor Unit AE160JXYDGH
  • Power Supply (Outdoor Unit) [Φ, #, V, Hz]
    • 3,4,380-415,50
  • System
    • Mode Heat Pump (A2W)
  • Capacity
    • Cooling [kW] 14.0 kW
    • Cooling [Btu/h] 47,800 Btu/h
    • Heating [kW] 16.0 kW
    • Heating [Btu/h] 54,600 Btu/h
  • Power Input (Nominal)
    • Cooling 1) 3.84 kW
    • Heating 2) 3.80 kW
  • Current Input (Nominal)
    • Cooling 1) 5.8 A
    • Heating 2) 5.7 A
  • Power
    • MCA [A] 12.0 A
    • MFA [A] 16.1 A
  • Energy Efficiency
    • EER (Nominal Cooling) 3.65
    • COP (Nominal Heating) 4.21
    • Energy Grade of Space Heater (55 ºC / 35 ºC) A+ / A++
    • Energy Grade of Package of Space Heater A+
  • Compressor
    • Type BLDC Twin Rotary
    • Model UG5T450FU
    • Oil (Type) PVE
  • Fan
    • Type Propeller
    • Air Flow Rate (High / Mid / Low) [CMM] 118 CMM
  • Condenser
    • Pipe Size (Φ, inch) BSPP male 1"
    • Water Flow Rate (LPM) 46 / 40 (Heating / Cooling)
  • Field Wiring
    • Transmission Cable 0.75 ~ 1.5
  • Refrigerant
    • Type R410A(Fluorinated greenhouse gas, GWP=2,088) 5.43tCO2e
    • Factory Charging (kg) 2.6 kg
  • Sound
    • Sound Pressure 52 / 54 (Heating / Cooling)
    • Sound Power 66 (Heating)
  • External Dimension (Outdoor Unit)
    • Net Weight(kg) 108 kg
    • Shipping Weight (kg) 118 kg
    • Net Dimensions (WxHxD) (mm) 940 x 1,420 x 330 mm
    • Shipping Dimensions (WxHxD) (mm) 995 x 1,598 x 426 mm
  • Operating Temp. Range
    • Cooling (℃) 10~46 ℃
    • Heating (℃) -25~35 ℃

Technical Support

Manual Download

EHS, Mono, Standard, Heat Pump (AE160JXYDGH/EU)

Manuals

2019.01.07

Installation Guide ver 1.0

(ENGLISH)