key features
-
World’s only Wind Free compatible
-
Advanced Flash Injection Compressor
-
Robust Frame
Rebuilt on all new innovations.
Rethink your approach to air conditioning with the Samsung DVM S2.It delivers outstanding comfort and energy efficiency, even in extreme climates. Its intelligent features make installation and maintenance easier and more cost-effective.
Perfectly compatible with WindFree™
Active Frequency Drive 10Hz
Enjoy continuous comfort and avoid wasting energy. Active Frequency Drive 10Hz technology enables the compressor to precisely control a small amount of refrigerant. So it maintains a more consistent temperature and is compatible with Samsung’s WindFree™ Cooling.
Enabling a new era ofconsistent comfort
Advanced Flash Injection Compressor
Enter a new era of non-stop comfort and efficiency. The Advanced Flash Injection Compressor provides the world’s largest capacity*. It combines Flash Injection technology with a strengthened Triple Profile Scroll and efficient Optimal Discharge Superheat (DSH) Control technology.
* Samsung circulates 14,400cc/sec refrigerant (= 90cc (displacement volume) x 160rps (revolutions per second)), while Company A circulates 12,480cc/sec (= 96cc x 130rps), Company B circulates 14,080cc/sec (= 88cc x 160rps) and Company C circulates 12,320cc/sec (= 88cc x 140rps).
- * Based on testing in accordance with the Eurovent testing rule, at the end of December 2020. Tested on 22.4~56kW models of the Samsung DVM S2 compared to the same capacities of another brand, using ducted type indoor units.
** Based on Samsung's measurements, comparing 33.6kW models of a DVM S2 and a conventional outdoor unit.
*** Based on internal testing, using the DVM S2 33.6kW model. A Multi-serration Fan generated 195CMM consuming 725W, while a conventional fan generated 176CMM consuming 1,057W. Results may vary depending on the individual test or usage conditions.
**** Based on internal testing of the DVM S2 33.6kW model compared to a conventional outdoor unit, combined with 6 GD2 5.6kW indoor units. Results may vary dependingon the individual test or usage conditions. - * Based on testing in accordance with the Eurovent testing rule, at the end of December 2020. Tested on 22.4~56kW models of the Samsung DVM S2 compared to the same capacities of another brand, using ducted type indoor units.
** Based on Samsung's measurements, comparing 33.6kW models of a DVM S2 and a conventional outdoor unit.
*** Based on internal testing, using the DVM S2 33.6kW model. A Multi-serration Fan generated 195CMM consuming 725W, while a conventional fan generated 176CMM consuming 1,057W. Results may vary depending on the individual test or usage conditions.
**** Based on internal testing of the DVM S2 33.6kW model compared to a conventional outdoor unit, combined with 6 GD2 5.6kW indoor units. Results may vary dependingon the individual test or usage conditions.
- * Optionally available depending on the installation conditions. For detailed information, please refer to the installation manual.
** Based on internal testing with an AM080AXVGGH/EU outdoor unit connected to AM083NN4DBH1 and AM145NN4DBH1 indoor units with 25m of piping, using the cooling operation in Auto mode for 4 hours, with an external temperature of 30°C of and a set temperature of 22°C. Results may vary depending on the actual installation and usage conditions, such as the piping length, elevation and external temperature.
*** Based on internal testing. Heating time at -10° over a period of 6 hours: Samsung DVM S2 (AM240AXVAGH/EU) = 180 minutes vs. conventional outdoor unit = 110 minutes. Results may vary depending on environmental factors and individual use. - * Optionally available depending on the installation conditions. For detailed information, please refer to the installation manual.
** Based on internal testing with an AM080AXVGGH/EU outdoor unit connected to AM083NN4DBH1 and AM145NN4DBH1 indoor units with 25m of piping, using the cooling operation in Auto mode for 4 hours, with an external temperature of 30°C of and a set temperature of 22°C. Results may vary depending on the actual installation and usage conditions, such as the piping length, elevation and external temperature.
*** Based on internal testing. Heating time at -10° over a period of 6 hours: Samsung DVM S2 (AM240AXVAGH/EU) = 180 minutes vs. conventional outdoor unit = 110 minutes. Results may vary depending on environmental factors and individual use. - * Optionally available depending on the installation conditions. For detailed information, please refer to the installation manual.
** Based on internal testing with an AM080AXVGGH/EU outdoor unit connected to AM083NN4DBH1 and AM145NN4DBH1 indoor units with 25m of piping, using the cooling operation in Auto mode for 4 hours, with an external temperature of 30°C of and a set temperature of 22°C. Results may vary depending on the actual installation and usage conditions, such as the piping length, elevation and external temperature.
*** Based on internal testing. Heating time at -10° over a period of 6 hours: Samsung DVM S2 (AM240AXVAGH/EU) = 180 minutes vs. conventional outdoor unit = 110 minutes. Results may vary depending on environmental factors and individual use.
Cost-effective and flexible design
Slimmer Liquid Pipe
Save installation cost with efficient piping. It uses 28% less refrigerant* as it can use a slimmer liquid pipe**. So it reduces installation and maintenance costs and improves design flexibility. It’s also environmentally friendly and reduces CO₂ emissions.
* When a slimmer pipe, instead of a normal pipe, is used for the Main Liquid Pipe on the same capacity of air conditioning system, the amount of refrigerant to be charged can be reduced by 28% on average.
** Optional. A slimmer pipe can be used for the Main Liquid Pipe, between an outdoor unit and the first branch of indoor units. The diameter of the slimmer pipe will vary depending on the diameter of the pipe that is normally used. Not available on the 22.4kW and 28kW models. It may not be available in certain installation conditions, and is not compatible with the AI functions of outdoor units. Please contact Samsung’s technical professionals regarding its availability and for more detailed information.
* When a slimmer pipe, instead of a normal pipe, is used for the Main Liquid Pipe on the same capacity of air conditioning system, the amount of refrigerant to be charged can be reduced by 28% on average.
** Optional. A slimmer pipe can be used for the Main Liquid Pipe, between an outdoor unit and the first branch of indoor units. The diameter of the slimmer pipe will vary depending on the diameter of the pipe that is normally used. Not available on the 22.4kW and 28kW models. It may not be available in certain installation conditions, and is not compatible with the AI functions of outdoor units. Please contact Samsung’s technical professionals regarding its availability and for more detailed information.
Reduces the disturbance of fan noise
Multi-serration Fan* & Diffuser Type Discharge Plenum
Reduce disturbance caused by air turbulence. A Multi-serration Fan* minimizes the air vortex and significantly reduces the fan noise. The discharge plenum’s edgeless, curved design also allows the fan to gently diffuse air without creating a vortex**.
* Only available on models of 33.6kW or less. The shape of the fan may vary by model and region.
** Based on internal testing and simulation using a fluid dynamics software, AnsysCFX. Results may vary depending on the actual usage conditions.
Prevents damagefrom shocks & vibration
Robust Frame
Reduce damage from shocks or earthquakes up to magnitude 9.0*. A new Robust Frame has reinforced corners, 25%** thicker sides and a refined shape. A Kammtail (KVF) bracket supports the motor with 210% more stiffness**. And redesigned legs suppress any sway.
* Based on a test in accordance with ICC ES AC156 : 2010 (SDS=2.5g, z/h=1), conducted by SGS Korea Co., Ltd. Result report No.: SGS-R20-1599-KR00.
** Based on internal testing using Siemens NX Nastran 1867 simulation.
Lasting protection,optimal performance
Durafin™ Ultra
Safeguard the Heat Exchanger from damaging corrosion. The Durafin™ Ultra has an anti-corrosive layer and a hydrophilic layer that protect the Heat Exchanger from rust. Its superb corrosion-resistance was proven in a Salt Spray Test (SST)*.
* Based on testing by a third party lab in accordance with ASTM B117, an official test method. For more details, please contact Samsung’s technical professionals.
** Based on testing by a third party lab, applying the actual pressure of refrigerant for 1 minute, after a Salt Spray Test (SST) of over 2,280 hours.
* Based on testing by a third party lab in accordance with ASTM B117, an official test method. For more details, please contact Samsung’s technical professionals.
** Based on testing by a third party lab, applying the actual pressure of refrigerant for 1 minute, after a Salt Spray Test (SST) of over 2,280 hours.
Anti-rust Protection extends working life
Galvanized Iron Steel Plate (GI)
Inhibit the formation of rust on the cabinet. It is made of Galvanized Iron Steel Plate (GI) with a PE powder coating that is up to 100µm thick, which improves corrosion-resistance by 43%*. It protects it from rusting, so it can endure harsh conditions.
* Based on internal testing using corrosion chambers, Q-FOG and CCT-1100. The Complex Cycle Test (CCT) includes cycles of spray (for 2 hours at 35°C), dry (for 4 hours at 60°C with 30% Relative Humidity) and damp (for 2 hours at 50°C with 95% Relative Humidity) conditions. As a result, the Galvanized Iron Steel Plate (GI) formed red rust after 240 hours, which is 43% slower than general Electro-Galvanized Steel Plate (EGI) which forms red rust after 168 hours.
* Based on internal testing using corrosion chambers, Q-FOG and CCT-1100. The Complex Cycle Test (CCT) includes cycles of spray (for 2 hours at 35°C), dry (for 4 hours at 60°C with 30% Relative Humidity) and damp (for 2 hours at 50°C with 95% Relative Humidity) conditions. As a result, the Galvanized Iron Steel Plate (GI) formed red rust after 240 hours, which is 43% slower than general Electro-Galvanized Steel Plate (EGI) which forms red rust after 168 hours.
Designed to perform in frozen climates
Upgraded Base Design & Base Heater
Make sure you are always comfortably warm. The DVM S2 delivers reliable heating in extremely cold weather. Its upgraded base design helps drain condensed water fast, so it can’t freeze, and a base heater* melts any ice that forms inside.
* Optional. Available in the second half of 2021. Varies based on the base size ofan outdoor unit.
* Optional. Available in the second half of 2021. Varies based on the base size ofan outdoor unit.
Easy troubleshooting with one touch
On-device Inverter Check™
Save time identifying system issues and the cost of specialist diagnostic tools. An On-device Inverter Check™ includes a one-touch button that lets you quickly check for device errors. It’s easy to access without removing the entire front cover.
Specifications
-
Cooling [Btu/h] 77000 Btu/h
-
Net Dimensions (WxHxD) (mm) 930x1695x765 mm