AC035JNNCEH/EU

CAC, 4-Way Cassette 600×600, Heat Pump, 3.5 kW

Ultra-compact size Attractive panel and display Light, robust design
Capacity 3.5 kW

Ideal Compact Size

Installing the Mini 4Way Cassette is easy. This compact air conditioning unit can fit into one standard ceiling tile measuring 600 W x 600 D, meaning that alterations are unnecessary. With no extra construction work to carry out, set-up time is reduced, as is the subsequent financial impact on businesses.

Ideal Compact Size

Fan Speed Adjustment

As a result of the ability to adjust the fan speed according to the height of the ceiling, the Mini 4Way Cassette is fully customisable to suit the needs of individual businesses. Altering the dual in-line package (DIP) switch of the unit's printed circuit board (PCB) increases efficiency so fresh air reaches the whole room, resulting in a more even distribution.

Fan Speed Adjustment

Auto Surround Swing

The innovative Twin Cross Flow Fan distributes cool and warm air even further with a minimum of noise. This efficient system suits rooms of any dimension so no corner is overlooked.

Auto Surround Swing

MDS: Motion Detect Sensor (Optional)

The Mini 4Way Cassette offers a smart solution to saving energy and costs with its optional Motion Detector Sensor (MDS), which regulates the optimal amount of airflow. It works by turning off the air conditioning system once it detects the absence of any users in the vicinity. Energy efficiency is further maximised through its ability to automatically identify and set operation patterns. MDS also reduces the contrasting effect of warm and cold airflow directly at individuals, thus creating a more constant and comfortable environment.

MDS: Motion Detect Sensor (Optional)
  • Powerful Airflow

    Powerful Airflow

    The 2 Way Cassette's wide blades create powerful airflow without wasting energy. Removing the need for multiple appliances, the indoor unit delivers cool or warm air at greater distances, making it more efficient for businesses. Providing even cooling and heating throughout the room, the 2 Way Cassette delivers optimal results, even in the remotest corners of the space.

  • Ceiling Dust Prevention

    Ceiling Dust Prevention

    Dirty ceilings are no longer an issue with the 2 Way Cassette air conditioning unit. The newly designed panel prevents dust from gathering over long periods of operation. By controlling the direction of the airflow so that it avoids contact with the ceiling, businesses can enjoy cleaner and more elegant work spaces than ever.

  • High Lift-Up Drain Pump

    High Lift-Up Drain Pump

    The 2 Way Cassette includes an optional high lift-up drain pump. This lifts condensed water up to 750 mm compared with previous 700 mm limits. The increased quantity provides more flexibility over where the unit is installed, offering users greater convenience than ever.

  • No Overflowing Drain Water

    No Overflowing Drain Water

    The innovative drain pump check valve prevents drained water from flowing backwards into the drain pan. Minimising the drain pan's water level in this way means businesses never have to worry about water stagnation or overflows that drip into indoor spaces. The 2 Way Cassette provides fresh, clean air without contaminating the room.

Specification
  • Features
    • Type CAC 4Way
  • Model Name
    • Indoor Unit AC035JNNCEH/EU
    • Outdoor Unit AC035JXSCEH/EU
  • System
    • Mode HEAT PUMP
  • Capacity
    • Cooling [kW] 0.90/3.50/4.20 kW
    • Cooling [Btu/h] 3,100/11,900/14,300 Btu/h
    • Heating [kW] 0.80/4.30/5.80 kW
    • Heating [Btu/h] 2,700/14,700/19,800 Btu/h
  • Power Input (Nominal)
    • Cooling 1) 0.19/0.94/1.26 kW
    • Heating 2) 0.16/1.18/1.65 kW
  • Current Input (Nominal)
    • Cooling 1) 1.30/4.40/5.80 A
    • Heating 2) 1.10/5.40/7.00 A
  • Power
    • MCA [A] 11.00 A
    • MFA [A] 12.50 A
  • Energy Efficiency
    • EER (Nominal Cooling) 3.72
    • COP (Nominal Heating) 3.64
    • Energy Grade (Cooling) A++ (7.60)
    • Energy Grade (Heating) A+ (4.50)
  • Piping Connections
    • Liquid Pipe (Φ, mm) 6.35 mm
    • Liquid Pipe (Φ, inch) 1/4"
    • Gas Pipe (Φ, mm) 9.52 mm
    • Gas Pipe (Φ, inch) 3/8"
    • Installation Max. Length [m] 20 m
    • Installation Max. Height [m] 15 m
  • Field Wiring
    • Power Source Wire 2.5~4.0
    • Transmission Cable 0.75 ~ 1.25
  • Refrigerant
    • Type R410A(Fluorinated greenhouse gas, GWP=2,088) 2.65tCO2e
    • Control Method EEV
    • Factory Charging (kg) 1.27 kg
  • Power Supply (Indoor Unit) [Φ, #, V, Hz]
    • 1,2,220-240,50
  • Fan
    • Type Turbo
    • Motor (Output) [W] 65 W
    • Number of Unit (EA) 1 EA
    • Air Flow Rate (High / Mid / Low) [CMM] 9.30/8.00/6.70 CMM
    • Air Flow Rate(High/Mid/Low)[L/S] 155.00/133.33/111.67
  • Drain
    • Drain Pipe (Φ,mm) VP25 (OD 32,ID 25)
  • Sound
    • Sound Pressure (High / Mid / Low) [dB(A)] 34 / 30 / 26 dBA
    • Sound Power (Cooling) [dB(A)] 51 dBA
  • External Dimension (Indoor Unit)
    • Net Weight(kg) 12.00 kg
    • Shipping Weight (kg) 14.00 kg
    • Net Dimensions (WxHxD) (mm) 575 x 250 x 575 mm
    • Shipping Dimensions (WxHxD) (mm) 623 x 298 x 653 mm
  • Panel Size
    • Panel model PC4SUSMAN / PC4SUSMEN
    • Panel Net Weight (kg) 2.70 kg
    • Shipping Weight (kg) 4.20 kg
    • Net Dimensions (WxHxD) (mm) 670 x 45 x 670 mm
    • Shipping Dimensions (WxHxD) (mm) 714 x 106 x 724 mm
  • Power Supply (Outdoor Unit) [Φ, #, V, Hz]
    • 1,2,220-240,50
  • Compressor
    • Type BLDC Rotary
    • Model DA128A1FA-20F(Toshiba)
    • Output(kW) 0.96 kW
    • Oil (Type) Ester oil VG74
    • Oil (Initial Charge) [cc] 450 cc
  • Fan (Outdoor Unit)
    • Air Flow Rate (Cooling) [CMM] 33.00 CMM
    • Air Flow Rate (Cooling) [L/S] 550.00
  • Sound (Outdoor Unit)
    • Sound Pressure (Cooling / Heating) [dB(A)] 47 / 48 dBA
    • Sound Power (Cooling) [dB(A)] 62 dBA
  • External Dimension (Outdoor Unit)
    • Net Weight(kg) 37.00 kg
    • Shipping Weight (kg) 39.00 kg
    • Net Dimensions (WxHxD) (mm) 790 x 548 x 285 mm
    • Shipping Dimensions (WxHxD) (mm) 926 x 640 x 384 mm
  • Operating Temp. Range
    • Cooling (℃) -20~50 ℃
    • Heating (℃) -25~24 ℃

Technical Support