AM071FN2DEH/EU

DVM, 2-WAY Cassette, Heat Pump

Capacity 7.1 kW
Ideal for Long and Narrow Places
Ideal for Long and Narrow Places

When indoor space is at a premium, the 2Way Cassette is an ideal solution, particularly in long narrow areas such as hallways and corridors. As it is 45 per cent smaller than previous units, and requiring 30 per cent less room than the 4Way cassette, it is easily incorporated into existing or planned building designs. Conveniently slotting into standard ceiling grids, the result is a discreet air conditioning system which offers maximum performance with minimum visual impact on decor.

Auto Surround Swing
Auto Surround Swing

The innovative Twin Cross Flow Fan distributes cool and warm air even further with a minimum of noise. This efficient system suits rooms of any dimension so no corner is overlooked.

Self-Diagnosis Mode
Self-Diagnosis Mode

The unit's self-diagnosis mode alerts users to malfunctions straight away. An error code and LED light enable engineers to identify the problem quickly, reducing the time taken to fix it.

Optimum Temperature Control
Optimum Temperature Control

Businesses benefit from a regular climate throughout the entire room with the Optimum Temperature Control feature. This function detects the temperature at the top and bottom of the area, then acts to minimise the difference maintaining optimum levels all around the room. As a result, hot and cold spots are eliminated, creating more balanced, comfortable surroundings.

  • Powerful Airflow

    Powerful Airflow

    The 2Way Cassette's wide blades create powerful airflow without wasting energy. Removing the need for multiple appliances, the indoor unit delivers cool or warm air at greater distances, making it more efficient for businesses. Providing even cooling and heating throughout the room, the 2Way Cassette delivers optimal results, even in the remotest corners of the space.

  • Ceiling Dust Prevention

    Ceiling Dust Prevention

    Dirty ceilings are no longer an issue with the 2Way Cassette air conditioning unit. The newly designed panel prevents dust from gathering over long periods of operation. By controlling the direction of the airflow so that it avoids contact with the ceiling, businesses can enjoy cleaner and more elegant work spaces than ever.

  • High Lift-Up Drain Pump

    High Lift-Up Drain Pump

    The 2Way Cassette includes an optional high lift-up drain pump. This lifts condensed water up to 750mm compared with previous 700mm limits. The increased quantity provides more flexibility over where the unit is installed, offering users greater convenience than ever.

  • No Overflowing Drain Water

    No Overflowing Drain Water

    The innovative drain pump check valve prevents drained water from flowing backwards into the drain pan. Minimising the drain pan's water level in this way means businesses never have to worry about water stagnation or overflows that drip into indoor spaces. The 2Way Cassette provides fresh, clean air without contaminating the room.

Specification
  • Features
    • Type 2 WAY CASSETTE
  • Model Name
    • Indoor Unit AM071FN2DEH/EU
  • Power Supply (Indoor Unit) [Φ, #, V, Hz]
    • 1, 2, 220 - 240, 50
  • System
    • Mode HP / HR
  • Capacity
    • Cooling [kW] 7.1 kW
    • Cooling [Btu/h] 24200 Btu/h
    • Heating [kW] 8 kW
    • Heating [Btu/h] 27300 Btu/h
  • Power Input (Nominal)
    • Cooling 1) [W] 75 W
    • Heating 2) [W] 75 W
  • Current Input (Nominal)
    • Cooling 1) 0.4 A
    • Heating 2) 0.4 A
  • Fan
    • Type Crossflow Fan
    • Motor (Output) [W] 14 x 2 W
    • Air Flow Rate (High / Mid / Low) [CMM] 15 / 14 / 13 CMM
    • Air Flow Rate(High/Mid/Low)[L/S] 250 / 233.33 / 216.67
    • External Static Pressure (Min / Std / Max) [mmAq] -
    • External Static Pressure (Min / Std / Max) [Pa] -
  • Piping Connections
    • Liquid Pipe (Φ, mm) 9.52 mm
    • Liquid Pipe (Φ, inch) 3 / 8"
    • Gas Pipe (Φ, mm) 15.88 mm
    • Gas Pipe (Φ, inch) 5 / 8"
    • Drain Pipe (Φ,mm) VP25 (OD 32, ID 25)
  • Field Wiring
    • Power Source Wire 1.5 ~ 2.5
    • Transmission Cable 0.75 ~ 1.5
  • Refrigerant
    • Type R410A(Fluorinated greenhouse gas)
    • Control Method EEV INCLUDED
  • Sound
    • Sound Pressure (High / Mid / Low) [dB(A)] 41 / 39 / 37 dBA
    • Sound Power 60 dBA
  • External Dimension (Indoor Unit)
    • Net Weight(kg) 22 kg
    • Shipping Weight (kg) 26 kg
    • Net Dimensions (WxHxD) (mm) 1030 x 650 x 230 mm
    • Shipping Dimensions (WxHxD) (mm) 1077 x 299 x 642 mm
  • Panel Size
    • Panel model PC2NUSMEN
    • Panel Net Weight (kg) 4 kg
    • Shipping Weight (kg) 8 kg
    • Net Dimensions (WxHxD) (mm) 1030 x 25 x 650 mm
    • Shipping Dimensions (WxHxD) (mm) 1103 x 151 x 727 mm
  • Additional Accessories
    • Drain Pump -
    • Drain Pump Max. Lifting Height/Displacement -
    • Air Filter -

Energy label, Fiche, ErP


Further Ecodesign and Energy labelling information : http://www.samsung.com/uk/business/system-air-conditioner/energylabel/

* Samsung air conditioners contain fluorinated greenhouse gas R410A with GWP=2088

Manual Download

DVM, 2-WAY Cassette, Heat Pump (AM071FN2DEH/EU)

Manuals

20 Jun, 2017

Installation Guide ver 1.0

(ENGLISH)

27 Feb, 2017

User Manual ver 1.0

(ENGLISH)

15 Apr, 2016

Safety Guide ver 1.0

(ENGLISH, CZECH, DUTCH, FRENCH, GERMAN, GREEK, HUNGARIAN, ITALIAN, POLISH, PORTUGUESE, RUSSIAN, SLOVAK, SPANISH)