AM100FNKDEH/EU

DVM S - Energy Ventilator System with DX Coil

Capacity 1000 ㎥/h

ERV Plus System Structure

Temperature Sensor
Automatic detection of indoor and outdoor temperature, enabling a switch to auto mode or executing the cold climate control function.

Dust Filter
Is designed to prevent dust from accumulating and blocking or contaminating the hear exchanger element.

Heat Exchanger Element
Transfers heat from exhaust air to fresh air.

Control Box
Contains electrical parts for product control.

Direct Expansion (DX) Coil
The new DX Coil heats and cools, enabling mode selection when ventilation is on.

Damper
Users can select between heat recovery and normal ventilation.

ERV Plus System Structure

Illustration indicative only. Actual effect will vary.

Heat Recovery Method of ERV System

Thanks to air inlets and outlets on both sides, the two way ventilation is designed to achieve superb efficiency. The Heat Recovery Method is designed to maintain indoor temperature and humidity during winter, and to keep rooms cool and dry during the summer.

Heat Recovery Method of ERV System

Flexible Installation

The option to install the ERV system horizontally is designed for convenience. By introducing ERV with the control boxes facing a single hole, businesses can install easily while cutting down on disruptions and also reduce space taken up by the unit. Unfortunately this is not applicable for ERV PLUS models.

Flexible Installation
Specification
  • Technical Information
    • Type ERV PLUS
  • Model Name
    • Indoor Unit AM100FNKDEH/EU
  • Convenience
    • 1,2,220-240,50
  • Airflow
    • Mode HP/HR
  • Capacity
    • Cooling (Min / Std / Max) 10.5 kW
    • Cooling [Btu/h] 35,800 Btu/h
    • Heating (Min / Std / Max) 13.2 kW
    • Heating [Btu/h] 45,000 Btu/h
  • Power Input (Nominal)
    • Cooling (Min / Std / Max) 0.510 kW
    • Heating (Min / Std / Max) 0.510 kW
  • Current Input (Nominal)
    • Cooling 1) 3.70 A
    • Heating 2) 3.70 A
  • Indoor Unit Fan
    • Type Sirroco Fan / BLDC
    • Motor (Output) [W] 70 x 2 W
    • Air Flow Rate(High/Mid/Low)[L/S] 277.83/277.83/191.67
    • External Static Pressure (Min / Std / Max) [mmAq] 7.60/9.20/15.30 mmAq
    • External Static Pressure (Min / Std / Max) 74.53/90.22/150.04 Pa
    • Air Flow Rate (High / Mid / Low) [m3/h] 1000/1000/690 ㎥/h
  • Piping
    • Liquid Pipe (Φ, mm) 6.35 mm
    • Liquid Pipe (Φ, inch) 1/4"
    • Gas Pipe (Φ, mm) 12.70 mm
    • Gas Pipe (Φ, inch) 1/2"
    • Drain Pipe (Φ,mm) VP25 (OD 32,ID 25)
  • Power Supply
    • Indoor (V) 1.5 ~ 2.5
    • Outdoor (V) 0.75 ~ 1.50
  • Refrigerant
    • Type R410A(Contains fluorinated greenhouse gas, GWP=2,088)
    • Required Circuit Size, A EEV INCLUDED
  • Noise Level (Outdoor)
    • Sound Pressure Level (Outdoor, High) 36/33/31 dBA
    • Sound Power 67.0 dBA
  • Physical Specification
    • Net Weight (Indoor) 90.0 kg
    • Net Weight (Outdoor) 107.5 kg
    • Unit Dimension (Indoor, WxHxD) 1763 x 340 x 1135 mm
    • Unit Dimension (Outdoor, WxHxD) 2027 x 428 x 1424 mm
Manual Download

DVM S - Energy Ventilator System with DX Coil (AM100FNKDEH/EU)

Manuals

2019.01.15

User Manual ver 1.0

(ENGLISH)